USB Digital Meter, USB-A and USB-C

ET920

  • 3 to 20V DC; Current: 0.05 to 3A (USB-A); 3 to 20V DC; Current: 0.05 to 5A (USB-C)
  • Continuously monitor up to 1000 hours of voltage, current, capacity/charge delivered, energy and resistance (calculated)
  • Tests most common standard USB-A or USB-C ports, including Qualcomm Quick Charge® ports
  • Store and recall up to 10 readings
  • Voltage and current overload detection
  • Hi-resolution LCD for clear visibility in environments with low ambient lighting
  • Device must be used in line between the source being measured and the power source
  • Rugged, pocket-sized and lightweight Klein industrial design stands up to jobsite demands
  • Built to withstand a 6.6' (2 m) drop
  • No batteries needed; powered by the USB port that is being tested
ce Product Icon
etl-intertek Product Icon
Videos
Images
High-Res JPG et920_photo_b.jpg

The Klein Tools ET920 is a USB digital meter for Type-A and Type-C ports. It accurately and reliably measures and displays the USB port voltage, current, capacity, energy and resistance simultaneously. It can function with any USB-A and most USB-C ports, including Qualcomm Quick Charge® ports that have the ability to deliver power. It requires NO batteries as it draws power from the power source to function.

Specifications
Type:
USB-A (Type A) and USB-C (Type C)
Application:
USB Port Voltage, Current, Capacity, Energy and Resistance (Calculated)
Special Features:
Fits any USB-A and USB-C ports
Voltage:
3 to 20V DC
Current:
USB-A: 0.05 to 3A; USB-C: 0.05-5A
Capacity used:
99999 mAh Maximum
Energy delivered:
999 Wh Maximum
Resistance:
400 Ohms Maximum
Elapsed time:
Up to 999 hours, 59 min, 59 secs
USB Compatibility:
USB-A, USB-C; Qualcomm Quick Charge® Compatible
Drop Protection:
2 m (6.6')
Ingress protection:
IP20
Display:
LCD
Material:
Polymer
Overall Length:
2.96'' (7.5 cm)
Overall Height:
0.6'' (1.5 cm)
Overall Width:
1.96'' (5 cm)
Weight:
1.70 oz (48.0 g)
UPC:
092644691669
Additional Information
Warnings
  • To ensure the safe operation and service of this meter, follow all instructions. Failure to observe these warnings can result in severe injury or death.
  • This meter will NOT display a current below 50 milliamperes, even if it is allowing this to pass through. NOTE: The display will show zero current.
  • Do NOT use with ports that operate outside of the rated voltage and current. NEVER use on a circuit with a voltage or current that exceeds the maximum specified for this device.
  • Do NOT use during electrical storms or in wet weather. Do NOT use if the meter appears to be damaged. Use caution when working with voltages above 25 V AC RMS or 24 V DC. Such voltages pose a shock hazard.