Infrared Thermometer with GFCI Receptacle Tester

IR1KIT

  • Infrared Thermometer (Cat. No. IR1) has an optical resolution (distance-to-spot) of 10:1
  • GFCI Outlet Tester (Cat. No. RT210) detects common wiring problems in standard and GFCI receptacles
  • Both products have a drop protection to 6.6' (2 m)
  • Infrared Thermometer has a wide measurement range from -4° F to 752 F (-20° C to 400° C)
  • Not a medical device; thermometer is NOT intended for use on people or animals
  • Fixed emissivity of 0.95 for the Infrared Thermometer
  • Infrared Thermometer includes custom pouch and a 9V battery
  • Auto Power-Off feature of the Infrared Thermometer conserves and extends battery life
  • Infrared Thermometer is Certified to IEC EN 61326-1.2006, EN608251.1994+A2.2001+A1.2002

The Klein Tools IR1KIT includes the Infrared Thermometer (Cat. No. IR1) and GFCI Receptacle Tester (Cat. No. RT210). The IR1 infrared thermometer with a targeting laser has a wide measurement range from -4°F to 752°F (-20°C to 400°C) and a 10:1 distance-to-spot ratio. The RT210 GFCI Receptacle Tester detects common wiring problems.

Specifications
Type:
Infrared Thermometer with Targeting Laser
Application:
Temperature Measurement and Electrical Testing
Special Features:
Target Laser on IR1
Material:
Plastic Housing, Electronic Components
Batteries:
1 x 9V
Distance to Spot:
10:1
Accuracy:
±4° F or ±2%; Accuracy Below Freezing is ±4° F plus 0.2 Degrees per Degree Below 32° F
Display:
Digital Backlit
Display Resolution:
0.1 F (0.1 C)
Response Time:
<0.25 s
Degree Format:
F or C
Range:
-4° to 752° F (-20° to 400° C)
Standard:
IR1: EN 61326-1:2013, EN 608251:2014, 21 CFR 1040.10 and 1040.11, Class II Laser, CE
Drop Protection:
6.6' (2 m)
Included:
RT210 GFCI Receptacle Tester; Custom Pouch; 1 x 9V Battery
Overall Length:
6.01'' (15.3 cm)
Overall Width:
1.24'' (3.1 cm)
Overall Height:
4.14'' (10.5 cm)
Weight:
7.1 oz (201 g)
UPC:
092644693199
Additional Information
Warnings
  • Read, understand and follow all instructions, cautions and warnings attached to and/or packed with all test and measurement devices before each use.
  • LASER RADIATION, Class II laser. Do NOT stare into the beam. Exposing eyes to laser radiation can result in severe and permanent eye injuries.
  • NEVER look directly into the laser beam emitted by this instrument.
  • Use of this tester in any way other than that specified by the manufacturer can impair safe operations, resulting in severe injury or death.
  • Thermometer is NOT intended for use on people or animals.