Electrical Tester, Open-Jaw Fork Meter, AC Auto-Ranging, 200 Amp

CL360

  • Open Fork Meter with automatically ranging True Root Mean Squared (TRMS) measurement technology for accuracy
  • Tester measures AC current via the clamp, and AC/DC voltage, resistance and continuity via test leads
  • Wide jaw for measuring current in cables up to 3/0 sizes; accommodates cables with diameters of up to 0.58'' (1.5 cm)
  • Non-contact voltage tester integrated into the jaw
  • Includes a carrying case, test leads and 2 x AAA batteries
  • Jaw and housing: CAT IV 600 V/CAT III 1,000 V; Electrical: CAT III 600 V/CAT II 1000 V; Class 2, Double insulation
  • Back-lit display for clear readings
  • Switches off automatically after 15 minutes of non-use to conserve battery life.
  • Rugged Klein TOUGH METER is built to withstand a 9.9-foot (3 m) drop
  • Low-battery indicator and easily accessible battery compartment
  • Meets requirements for use in basic and controlled electromagnetic environments such as residential, office and light-industrial locations
ce Product Icon
etl-intertek Product Icon
tough-meter Product Icon
drop_protection-3m Product Icon
Videos

The CL360 Electrical Tester is an automatically ranging true root mean squared (TRMS) digital open jaw fork meter that measures AC current via the fork, AC/DC voltage, continuity and resistance via test leads. It can detect the presence of a voltage via the integrated non-contact voltage (NCV) tester. It includes a carrying case, test leads and 2 x AAA batteries.

Specifications
Type:
Open-Jaw Fork Current Meter
Application:
Measures AC current, AC/DC voltage, continuity and resistance
Special Features:
Low-battery indicator, built-in test lead holders, back-lit display
Material:
Plastic/electronics
Batteries:
2 x AAA
Auto Shut Off:
Y
Jaw Size:
0.58'' (1.5 cm) Opening
Drop Protection:
9.9' (3m)
Display:
6,000-count LCD
Functions:
AC current, AC/DC voltage, continuity, resistance
Voltage:
600 V AC, 1,000 V DC
Current:
200A AC
Ohms (Resistance):
60MΩ
AC Voltage:
600V
DC Voltage:
1000V
DC Polarity Indicator:
Yes
Ingress Protection:
IP40
Standard:
Jaw and Housing: CAT IV 600 V/CAT III 1,000 V; Electrical: CATIII 600V/CATII 1000V
Included:
Electrical Tester; Carrying Case; Instruction Manual; Straight Input Test Leads; 2 x 1.5V AAA Batteries
Overall Length:
8.39'' (21.3 cm)
Overall Height:
1.38'' (3.5 cm)
Overall Width:
2.12'' (5.4 cm)
Weight:
6.40 oz (180.0g)
UPC:
092644691140
Additional Information
Warnings
  • Read, understand and follow all instructions, cautions and warnings attached to and/or packed with all test and measurement devices before each use.
  • Before every use, verify the meter operation by measuring a known voltage or current.
  • Never use the meter on a circuit with voltages that exceed the category-based rating of this meter.
  • Always adhere to local and national safety codes. Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
  • Usage of this meter in any way other than that specified by the manufacturer can impair safe operations, resulting in severe injury or death.